EVERGREEN SYSTEMS, INC.

CAPSERVER MODELS 325E, 425, 440E

Processor

AM386SX/CX486SLC/80386SX/TI486SXLC2

Processor Speed

25/40MHz

Chip Set

Unidentified

Max. Onboard DRAM

16MB

Cache

None

BIOS

Unidentified

Dimensions

Unidentified

I/O Options

10-baseT Ethernet connector, floppy drive interface, IDE interface, parallel port, proprietary display connector, serial ports (2), thin Ethernet connector, VGA port

NPU Options

80387SX

CONNECTIONS

Purpose

Location

Purpose

Location

Thin Ethernet connector

BNC

Speaker

J12

Proprietary display/CAPlink

DISP

External battery

J13

Floppy drive interface

FLP

Parallel port

PAR

IDE interface

IDE

Serial port 1 (10-pin modular)

SER1

Keylock

J6

Serial port 2

SER2

Alternate keyboard

J7

Ethernet 10BaseT connector

TBT

Reset switch

J11

VGA port

VGA

USER CONFIGURABLE SETTINGS

Function

Jumper

Position

»

Onboard VGA controller enabled

W1

Closed

 

Onboard VGA controller disabled

W1

Open

»

VGA IRQ9 disabled

W2

Open

 

VGA IRQ9 enabled

W2

Closed

»

Ethernet select 10BaseT

W3

pins 1 & 2 closed

 

Ethernet select thin

W3

pins 2 & 3 closed

»

AT bus disabled (Capcard only receives DC from backplane)

W4

Open

 

AT bus enabled (Capcard may drive peripheral cards)

W4

Closed

»

IDE interrupt select edge triggered

W5

pins 1 & 2 closed

 

IDE interrupt select level triggered

W5

pins 2 & 3 closed

»

Floppy drive IRQ6 enabled

W6

Closed

Floppy drive IRQ6 disabled

W6

Open

Note: Only one card in a segment can have W4 closed. Damage will result otherwise. See Below.

DRAM CONFIGURATION TABLE

Size

Bank 0

Bank 1

2MB

(2) 1M x 9

NONE

4MB

(2) 1M x 9

(2) 1M x 9

10MB

(2) 1M x 9

(2) 4M x 9

16MB

(2) 4M x 9

(2) 4M x 9

CAPCARD ID CONFIGURATION

ID#

SW1/1

SW1/2

SW1/3

SW1/4

SW1/5

1

Off

Off

Off

Off

On

2

Off

Off

Off

On

Off

3

Off

Off

Off

On

On

4

Off

Off

On

Off

Off

5

Off

Off

On

Off

On

6

Off

Off

On

On

Off

7

Off

Off

On

On

On

8

Off

On

Off

Off

Off

9

Off

On

Off

Off

On

10

Off

On

Off

On

Off

11

Off

On

Off

On

On

12

Off

On

On

Off

Off

13

Off

On

On

Off

On

14

Off

On

On

On

Off

15

Off

On

On

On

On

16

On

Off

Off

Off

Off

17

On

Off

Off

Off

On

18

On

Off

Off

On

Off

19

On

Off

Off

On

On

20

On

Off

On

Off

Off

21

On

Off

On

Off

On

22

On

Off

On

On

Off

23

On

Off

On

On

On

CAPCARD ID CONFIGURATION

ID#

SW1/1

SW1/2

SW1/3

SW1/4

SW1/5

24

On

On

Off

Off

Off

25

On

On

Off

Off

On

26

On

On

Off

On

Off

27

On

On

Off

On

On

28

On

On

On

Off

Off

29

On

On

On

Off

On

30

On

On

On

On

Off

Note: Capcard ID’s are necessary for the card to distinguish between cards. #1 is considered the server.

RESTORING FACTORY DEFAULTS

Setting

SW1/6

SW1/7

SW1/8

Normal operation

Off

Off

Off

Restore defaults boot from 1.44MB A:

On

Off

Off

Restore defaults boot from 40MB C:

Off

On

Off

Restore defaults boot from Novell network

Off

Off

On

Suppress EEPROM overide and use CMOS

Off

On

On

USER CONFIGURABLE SETTINGS

Function

Jumper

Position

»

Interprocessor Communications Unit enabled

W7/IPCU DIS

Open

 

Interprocessor Communications Unit disabled

W7/IPCU DIS

Closed

»

Onboard drive controllers enabled

W7/FDCIDE DIS

Open

 

Onboard drive controllers disabled

W7/FDCIDE DIS

Closed

»

Factory configured - do not alter

W7/SCC SEL2

Open

»

Factory configured - do not alter

W7/SCC SEL1

Open

»

Factory configured - do not alter

W8/ all

Open

»

Factory configured - do not alter

W9/ all

Open

»

Factory configured - do not alter

W14/ all

Open

PRIMARY SERIAL PORT CONFIGURATION

Port address

W7/COM1 SEL1

W7/COM1 SEL2

COM1

Open

Open

COM2

Closed

Open

COM3

Open

Closed

Disabled

Closed

Closed

SECONDARY SERIAL PORT CONFIGURATION

Port address

W7/COM2 SEL1

W7/COM2 SEL2

COM1

Open

Open

COM2

Closed

Open

COM3

Open

Closed

Disabled

Closed

Closed

PARALLEL PORT CONFIGURATION

Port address

W7/PAR SEL1

W7/PAR DIS

LPT1

Open

Open

LPT2

Closed

Open

Disabled

Open

Closed

ENET ADDRESS CONFIGURATION

Address

W7/ENET SEL1

W7/ENET SEL2

W7/ENET DIS

300h

Open

Open

Open

320h

Closed

Open

Open

340h

Open

Closed

Open

360h

Closed

Closed

Open

Disabled

Open

Open

Closed

ENET INTERRUPT CONFIGURATION

Interrupt

W10/IRQ3

W10/IRQ4

W10/IRQ5

W10/IRQ9

IRQ3

Closed

Open

Open

Open

IRQ4

Open

Closed

Open

Open

IRQ5

Open

Open

Closed

Open

IRQ9

Open

Open

Open

Closed

PARALLEL PORT INTERRUPT CONFIGURATION

Interrupt

W11/IRQ5

W11/IRQ7

IRQ5

Closed

Open

IRQ7

Open

Closed

Disabled

Open

Open

SERIAL PORT INTERRUPT CONFIGURATION

Port

W12/IRQ3

W12/ IRQ4

COM1

pins COM1 & IRQ3 closed

pins COM1 & IRQ4 closed

COM2

pins COM2 & IRQ3 closed

pins COM2 & IRQ3 closed

Note: Names represent pins in diagram. The diagram shows COM1 at IRQ4 and COM2 at IRQ3.

IPCU INTERRUPT CONFIGURATION

Interrupt

W13/IRQ7

W13/IRQ11

W13/IRQ12

W13/IRQ15

IRQ7

Closed

Open

Open

Open

IRQ11

Open

Closed

Open

Open

IRQ12

Open

Open

Closed

Open

IRQ15

Open

Open

Open

Closed

WARNING

ONLY ONE CARD IN A GIVEN SEGMENT OF THE ABOVE BACKPLANES MAY HAVE ITS AT BUS

JUMPER INSTALLED AT W4.

IF MORE THEN ONE CARD HAS W4 INSTALLED DAMAGE WILL OCCUR.

TERMINATING RESISTOR CONFIGURATION

Setting

R100

First and last CAPcards in CAPserver

Installed

All other cards in CAPserver

Not installed