ARCHIVE CORPORATION

SC402

Card Type

Tape drive controller

Chip Set

Unidentified

Maximum Onboard Memory

Unidentified

I/O Options

1/4 inch cartridge tape drive

Tape Format

QIC 11, QIC 24

Data Bus

8-bit ISA

CONNECTIONS

Function

Label

Function

Label

Tape drive connector - external

J2

Tape drive connector - internal

J3

USER CONFIGURABLE SETTINGS

Function

Label

Position

»

Factory configured - do not alter

RR

Open

DMA CHANNEL SELECTION

Channel

JP6

JP5

JP4

JP3

JP2

JP1

»

1

Closed

Open

Open

Closed

Open

Open

 

2

Open

Closed

Open

Open

Closed

Open

 

3

Open

Open

Closed

Open

Open

Closed

BASE I/O ADDRESS SELECTION

Setting

CMP3

CMP4

CMP5

CMP6

CMP7

CMP8

CMP9

CMP10

 

0h

On

On

On

On

On

On

On

On

 

8h

Off

On

On

On

On

On

On

On

 

10h

On

Off

On

On

On

On

On

On

 

18h

Off

Off

On

On

On

On

On

On

 

20h

On

On

Off

On

On

On

On

On

»

200h

On

On

On

On

On

On

Off

On

 

3D8h

On

On

Off

On

On

On

On

On

 

3E0h

Off

Off

On

On

On

On

On

On

 

3E8h

On

Off

On

On

On

On

On

On

 

3F0h

Off

On

On

On

On

On

On

On

 

3F8h

On

On

On

On

On

On

On

On

Note:

A total of 128 base address settings are available. The jumpers are a binary representation of the decimal memory addresses. Jumper CMP9 is the Most Significant Bit and jumper CMP3 is the Least Significant Bit. The jumpers have the following decimal values: CMP9=512, CMP8=256, CMP7=128, CMP6=64, CMP5=32, CMP4=16, CMPA3=8. Jumper CMP10 is always on. Turn off the jumpers and add the values of the jumpers and convert to hexadecimal to obtain the correct memory address. (Off=1, On=0)

INTERRUPT SELECTION

IRQ

JP7

JP8

JP9

JP10

JP11

JP12

 

IRQ2

Open

Open

Open

Open

Open

Closed

»

IRQ3

Open

Open

Open

Open

Closed

Open

 

IRQ4

Open

Open

Open

Closed

Open

Open

 

IRQ5

Open

Open

Closed

Open

Open

Open

 

IRQ6

Open

Closed

Open

Open

Open

Open

 

IRQ7

Closed

Open

Open

Open

Open

Open

DIAGNOSTIC LED(S)

Note: The function of the LEDs is unidentified, however on power up or reset all LEDs will light up. When the reset or self test is completed the LEDs will turn off.