M 2 2 6 2 E FUJITSU NO MORE PRODUCED Native| Translation ------+-----+-----+----- Form 5.25"/FH Cylinders 1658| | | Capacity form/unform 448/ 570 MB Heads 11| | | Seek time / track 16.0/ 4.0 ms Sector/track 53| | | Controller ESDI Precompensation 65535 Cache/Buffer KB Landing Zone Data transfer rate 1.875 MB/S int Bytes/Sector 512 5.000 MB/S ext Recording method RLL 1/7 operating | non-operating -------------+-------------- Supply voltage 5/12 V Temperature *C 5 45 | -40 60 Power: sleep W Humidity % 20 80 | 5 95 standby W Altitude km 3.000| 12.000 idle W Shock g 2 | 20 seek W Rotation RPM 3600 read/write 28.0 W Acoustic dBA spin-up W ECC Bit - MTBF h 30000 Warranty Month Lift/Lock/Park YES Certificates ********************************************************************** L A Y O U T ********************************************************************** FUJITSU M2261E/M2262E/M2263E OEM MANUAL 41FH5031E-02 +---------------------------------------------------------+ | 16+----+2 |XX 20 Pin | 15+CNH7+1 |XX | +---+CN4 16+----+2 |XX | +---+CN5 15+CNH6+1 15+-+16 |XX | +---+CN6 | | +--------+ | | +---+ CNH5| +Terminat+ |XX 34 Pin | 1+-+2 |XX | 15+-+16 |XX | CNH2| |XX | | | |XX | 16+----+2 1+-+2 |XX | 16+----+2 15+CNH1+1 |XX | 15+CNH3+1 1+-+2|XX | CN7 | | | | | | | 16+----+2 3210 5+-+6|XX Power | 15+CNH4+1 **** Fault Lamp |XX +---------------------------------------------------------+ ********************************************************************** J U M P E R S ********************************************************************** FUJITSU M2261E/M2262E/M2263E OEM MANUAL 41FH5031E-02 Fault Lamps and Setting Plugs ============================= Selectable by user side: Terminator CNH5, CNH6, CNH7 Fixed at factory: CN4, CN5, CN6, CN7 CNH1, CNH2, CNH3, CNH4 Jumper Settings =============== x = Jumpers are set from factory CNH3 Offtrack Compensation --------------------------- 15-16 OPEN Enable CLOSE Disable CNH5 READY LED lighting conditions ----------------------------------- x 15-16 OPEN Drive select signal not gated CLOSE Drive select signal gated CNH6 Drive select ------------------ Drive 1 2 3 4 5 6 7 ------+-----+-----+-----+-----+-----+-----+----- x 1- 2 |CLOSE|OPEN |OPEN |OPEN |OPEN |OPEN |OPEN 3- 4 |OPEN |CLOSE|OPEN |OPEN |OPEN |OPEN |OPEN 5- 6 |OPEN |OPEN |CLOSE|OPEN |OPEN |OPEN |OPEN 7- 8 |OPEN |OPEN |OPEN |CLOSE|OPEN |OPEN |OPEN 9-10 |OPEN |OPEN |OPEN |OPEN |CLOSE|OPEN |OPEN 11-12 |OPEN |OPEN |OPEN |OPEN |OPEN |CLOSE|OPEN 13-14 |OPEN |OPEN |OPEN |OPEN |OPEN |OPEN |CLOSE CNH6 Signal gate or not (Select signal) ---------------------------------------- x 15-16 OPEN Gate (daisy) CLOSE No gate (radial) When the pins are shorted, the drive output signals are always enabled, regardless of Drive Select signal. Without a jumper here, the output signals are enabled only when the drive is selected. CNH7 Motor start control from interface ---------------------------------------- 1- 2 OPEN Yes x CLOSE No CNH7 Device Type selection (model specific) -------------------------------------------- Device M2261 M2262 M2263 ------+-----+-----+----- 3- 4 |OPEN |OPEN |CLOSE 5- 6 |OPEN |CLOSE|OPEN CNH7 Sector setting -------------------- Sectors/Track 24 27 28 48 51 53 54 96 Bytes/Sector |1304 |1159 |1117 | 652 | 613 | 590 | 579 | 362 -------------+-----+-----+-----+-----+-----+-----+-----+----- x 7- 8 |OPEN |OPEN |OPEN |OPEN |CLOSE|CLOSE|CLOSE|CLOSE x 9-10 |OPEN |OPEN |CLOSE|CLOSE|OPEN |OPEN |CLOSE|CLOSE x 11-12 |OPEN |CLOSE|OPEN |CLOSE|OPEN |CLOSE|OPEN |CLOSE Valid only in hard sector mode CNH7 Sector mode setting ------------------------- 13- 14 OPEN Drive hard sector CLOSE Controller soft sector CNH7 Power ON Reset Condition ------------------------------ x 15- 16 OPEN ATTENTION signal and bit 8 of Status byte are set at the READY state just after power-on. CLOSE ATTENTION signal and bit 8 of Status byte are not set at the READY state just after power-on. Fault lamps =========== Drive fault states are displayed by the fault lamps (0,1,2,3) Fault lamp| Drive State 3 2 1 0 | ----------+-------------------------------------------------- x x x o | Spindle motor rotation less than 90% of standard x x o x | VCM over current x x o o | Initial seek time out x o x x | Write command during seek operation x o x o | +12V/+5V less than 80% of standard x o o x | Off track during Write operation x o o o | Write Echo check o x x x | Two or more head ICs selected during | operation o x x o | Seek time out o x o x | Guard band detection during Seek operation o x o o | Guard band detection during linear mode o o x x | Overshoot check o o x o | Seek command without ONTRACK signal true o o o x | Head load signal lost after READY o o o o | Read and Write commands simultaneously issued or | other miscellaneous faults x x x * | Invalid or unimplemented command fault x x * x | Interface time out fault x x * * | Command data parity fault x * x x | Spindle sync error o = On x = Off * = Blinking ********************************************************************** I N S T A L L ********************************************************************** FUJITSU M2261E/M2262E/M2263E OEM MANUAL 41FH5031E-02 Notes on installation ===================== Installation direction ---------------------- horizontally vertically +-----------------+ +--+ +--+ | | | +-----+ +-----+ | | | | | | | | | +-+-----------------+-+ | | | | | | +---------------------+ | | | | | | | | | | | | x x | | | | | | +------x------x-------+ | +-----+ +-----+ | +-+------x--x-------+-+ +--+ +--+ | xx | | x x | +---x--------x----+ x x There are three possible installation directions, and the mounting angle must be 5* from the horizontal. Ambient temperature ------------------- The operating temperature range of the drive is specified at a dis- tance of 3 cm from the drive. Note, temperature specifications are for the outside air surrounding the drive. Multi-drive connection ---------------------- In serial mode, up to 7 drives can be connected. The termination of the control signals must be performed only at the last drive. The terminator must be removed from all but the last drive. ********************************************************************** F E A T U R E S ********************************************************************** FUJITSU M2261E/2262E/2263E OEM MANUAL 41FH5031E-02 Defect list =========== When the unit leaves the factory, a printed media defect list for each drive is sent with it. This information is also written on the media. Cylinder 0, Head 0 and 1 are defect free!