PRACTICAL ENHANCED LOGIC, CORP.

PEL - 1600 SERIES

Data bus:

16-bit ISA

Size:

Three/quarter-length, full-height card

Hard drive supported:

Up to seven SCSI drives

Floppy drives supported:

Two 360KB, 720KB, 1.2MB, or 1.44MB drives

CONNECTIONS

Function

Location

34-pin cable connector - floppy drive

J1

50-pin SCSI connector - internal

J2

4-pin connector - drive active LED

J3

25-pin parallel port - external

J4

USER CONFIGURABLE SETTINGS

Function

Location

Setting

»

Factory configured - do not alter

S1/1

off

»

Factory configured - do not alter

S1/2

off

»

Factory configured - do not alter

S1/3

off

»

Factory configured - do not alter

S1/4

off

»

Floppy drive enabled

S1/5

on

 

Floppy drive disabled

S1/5

off

»

SCSI termination enabled

S2/7

on

 

SCSI termination disabled

S2/7

off

»

Parallel port address is 340h - 350h

S2/8

off

 

Parallel port address is 140h - 150h

S2/8

on

BIOS ADDRESS SELECTION

Address

S1/6

S1/7

S1/8

C800h - CBFFh

off

off

off

CC00h - CFFFh

on

off

off

D000h - D3FFh

off

on

off

D400h - D7FFh

on

on

off

D800h - DBFFh

off

off

on

DC00h - DFFFh

on

off

on

Disabled

off

on

on

Disabled

on

on

on

INTERRUPT SELECTION

IRQ

S2/1

S2/2

S2/3

S2/4

S2/5

S2/6

»

11

off

off

on

off

off

off

 

5

on

off

off

off

off

off

 

10

off

on

off

off

off

off

 

12

off

off

off

on

off

off

 

14

off

off

off

off

on

off

 

15

off

off

off

off

off

on